Skip to main content

Posts

Showing posts with the label Cape Town

Part 8: Renewable Energy System Design - "DIY Sizing"

Let's get around to looking at some calculations. I suggest that you sit down with a piece of paper and a pen so that you can work through this example with me. The problem: During a 4 hour Eskom power failure, you want to run your computer for 4 hours and it uses 300 Watts (per hour); you also want to run 4 lights for 4 hours. Each light draws 8 Watts. You don't want to use a noisy, smelly and pollution generating generator. You want to build a system yourself and one day add a solar panel or solar array to it. You are prepared to spend a bit extra to make that "start" in Renewable Energy. Renewable Energy "Thinking" Notes: Eskom energy is still much cheaper than generator energy, so we'll start with charging the battery using Eskom energy. Eskom energy isn't clean, but we need a starting point. We can add solar and other technologies to this system later. My Eskom energy (electricity) at the moment is about 70 cents per kwh. This in May 20...